Turbina de vapor DRESSER-RAND RD9MOQ

energía & motores: generadores eléctricos, motores, turbinas, calderas / generadores eléctricos

Fabricante: DRESSER-RAND

Modelo:RD9MOQ

Tipo de máquina: Turbina de vapor

Número de artículo: 166201256

Cantidad: 1

Fecha: 30.05.2025

Año de fabricación: 2009

Ubicación: Germany

Precio:


Seller-item-No.:5492178

3X Identical Steam Turbine sets

Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required.

The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz.

Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine.

The unused steam turbine sets are packed in wooden crates in a seaworthy condition. The individual parts are packed airtight in aluminum-coated plastic.

If an interested party expresses a serious interest in purchasing one set, the parts can be unpacked accordingly for an inspection.

The unused steam turbine sets are still in good condition. A few years ago, the generators have been tested as good. Out of the former 4 steam U5558834 turbine sets, one has already been sold four years ago and no negative feedback has been received.

Below are a few key data:

- Manufacturer turbine: Dresser-Rand
- TYPE: RD9MOQ
- Generator: INDAR Syn. Generator 3 Phases
- Gearbox: COLOR 4,500 rpm/1,800 rpm
- Condenser: GEA
- Grid frequency: 60 Hz
- Capacity: 12,3 MW
- Steam inlet pressure: 42 bar
- Temperature: rd. 420 degrees
- Steam exhaust temperature: rd. 40 degrees
- Steam consumption at 9 to 10 MW: rd. 40 tons
- Generation: power, no cogeneration of steam

Find more here - /

Contact us at -
Comparte esta máquina en Facebook:

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

¿Copia a usted?

Save input data

3X Identical Steam Turbine sets

Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required.

The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz.

Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine.

The unused steam turbine sets are packed in wooden crates in a seaworthy condition. The individual parts are packed airtight in aluminum-coated plastic.

If an interested party expresses a serious interest in purchasing one set, the parts can be unpacked accordingly for an inspection.

The unused steam turbine sets are still in good condition. A few years ago, the generators have been tested as good. Out of the former 4 steam U5558834 turbine sets, one has U5558834 already been sold four years ago and no negative feedback has been received.

Below are a few key data:

- Manufacturer turbine: Dresser-Rand
- TYPE: RD9MOQ
- Generator: INDAR Syn. Generator 3 Phases
- Gearbox: COLOR 4,500 rpm/1,800 rpm
- Condenser: GEA
- Grid frequency: 60 Hz
- Capacity: 12,3 MW
- Steam inlet pressure: 42 bar
- Temperature: rd. 420 degrees
- Steam exhaust temperature: rd. 40 degrees
- Steam consumption at 9 to 10 MW: rd. 40 tons
- Generation: power, no cogeneration of steam

Find more here - /

Contact us at -
seller offer No. resale 5492178
Comparte esta máquina en Facebook:

Vendedor

logo dealer

UCY Industrial GmbH

Señor Nick Breinfalk
82049 Pullach
Germany

RESALE miembro desde 2024

  • lista de máquinas (1379)

Pregunta

Distribuidor de la maquinaria?

Por favor remitir opcionalmente

Enviar la pregunta deseada?

(a todos los vendedores y compradores de dicha máquina)

¿Copia a usted?

(copia de su preguna será enviado a su dirección de correo electrónico)

Save input data

(Save input data for further inquiries)

Precio: sold Dresser-Rand RD9MOQ + similares Dresser-Rand-Modelo

2009 DRESSER-RANDRD9MOQ 560000 EUR [Nov 2017]