TO WHOM IT MAY CONCERN; WE VE GENUINE 3 PCS MAN NR 34 / S 114. COMPLETE EXHAUST GAS TURBOCHARGER WITH SILENCER AT AT OUR STOCK. IT IS OVERHAULED & TESTED ON TRIAL ENGINE OPERATION . PLS FIND SPECT AT BELOW. TYPE NR34 / S 114 SERIAL NO SMM0965 t max . 650 C n max 26300 1/min YOB 2012 -09 . MADE IN MAN ENTPACO IF YOU VE ANY FURTHER QUESTIONS PLS DO NOT HESITATE TO CONTACT WITH US . Capt. Ayhan Ugurluba BEST REGARDS; Aliaga marine services E mail: info/aliagamarine.com PHN/fax: +90 232 618 03 90 Mobile: + 905556084850 aliagamarine.com TURKEY
FOR SALE... OVERHAULED TURBOCHARGERS ABB VTR 254-11 & BBC VTR 214-11 TO WHOM IT MAY CONCERN; WE VE BELOW LISTED OVERHAULED & REPORTED TURBO CHARGERS AT OUR STOCK. READY TO TRANSPORT AND USE... ABB VTR 254-11 HZTL 428765P2 nNmax 523 nBmax 497 tMmax 680 C tBmax-650 C SFUSO1 YEAR OF BUILT 2010 BBC VTR 214-11 NoHT 399285 their 635 Tmax 680 V 01113 R 012 H 04109 W 12206 E 03221 U 023 YEAR OF BUILT 2012 IF YOU'VE ANY FURTHER QUESTIONS PLS DO NEED HESITATE TO CIONTACT WITH US. Capt. Ayhan Ugurluba BEST regards; Aliaga marine services E mail: info/aliagamarine.com PHN/fax: +90 232 618 03 90 Mobile: + 905556084850 aliagamarine.com TURKEY
HAVE A GOOD DAY SIR. WE VE NEW UNUSED. MITSUI MAN NA 57 TO 725 P IT STOWED AT FABRIQ WOODEN BOX. IT WILL NEVER MOUNTED AND USED. PLS FIND SPEC AT BELOW. READY TO TRANSPORT. EX STOCK. MITSUI MAN: NA 57 TO 725 P NO.: 2430 SPEC AD: 490 A4K : 404.3 REVOLUTION: 15000 RPM MAX TEMP: 600 C IF YOU'VE ANY FURTHER QUESTIONS PLS DO EMERGENCY HESITATE TO CONTACT WITH US. READY TO TRANSPORT. EX STOCK. Capt. Ayhan Ugurluba Best Regards ; Aliaga marine services E mail: info@aliagamarine.com PHN/fax: +90 232 618 03 85 Mobile: + 905556084850 ABC.aliagamarine.com TURKEY
MAN NR34/S026 turbines 1 new and 3 used available New bearings and repair sets also available in our stock in Istanbul Please contact: info@fin-marine ... more information
new gas turbine packages 16 MW each possible with OEM guarantee 50 Hz gas fired ... more information
Biomass Plant, 5 MWel, 50 Hz, yoc 2002, in operation Boiler • Technical data: - Fuel tank capacity: approx. 1 .300 m 3 - Exhaust gas volume 29,000 Nm3/h - Average combustion temperature of 900°C (850 for 2 s.) - Thermal power of the furnace 13 MW - 2 add. Burners 5 MW each - Average calorific value Hu 12,500 kJ/kg - Throughput capacity 3,991 kg/h - Boiler working pressure 41 bar - Superheated steam temperature 420°C - designed amount of steam 14 t/h - Fuels: RDF, wood chips, straw, remains of chipboard, choiceed waste Hours of operation of the entire plant appr. 120,000 hours Steam turbine - TWIN steam turbine KKK, type: CFR 3 / AFA 6 GTA - Generator AvK, type DIG 140 k/4W - Gearbox Renk, type: ELCO W-shape can be inspected in operation this week, - SGS can be ordered for inspection.
SGT 400 YOC 2010, 10.000 hours only 6 years in operation at peak load conserved 50 Hz 11 kV 14,300 kVA 1500 rpm still complete installed. relocation can be offered ... more information
Gas turbine with generator model M1A-13D 2,500 hours after overhaul 50 Hz, 400 V, in excellent condition, extrated and ready for transport. ... more information
Manufacturer: Solar Turbines INC, San Diego USA Model: Taurus 60 with Solonox combustion, Packager: Turbomach Version: T 7301 Yoc package: 1998 Turbine engine: new engine installed in 2012, only few hours since installation Condition: fully serviced and ready for start. Capacity: 5200 kW Speed: 14.944 U/min continual Fuel: Natural Gas and Light Diesel (dual fuel) Fuel consumption: 122.469 kJ/kWh Burners: 12 Start system: electro.hydraulic, 90 kW Outlet temperature: 486°C Exhaust gas: 21.244 kg/s
Titan 130 package Year of construction 2005, new turbine, NOT overhauled 15.000 hours 11.8 MW 50 Hz Installed and in standby condition, maintained by Turbomach, immediately possible to extract and ship for exchange purpose ... more information
Steam turbine Type: B + V, MARC2 - B10, back pressure with extraction Live steam pressure 58 bar 60.5 bar max Live steam temp.: 510 ° C Steam quantity: 45 t / h Extraction pressure: 21 bar 24.0 bar max Extraction temp.: 383 ° C 490 ° C max Extraction quantity: 7 t / h t 15 / h max Exhaust pressure: 3 bar 4 bar max Exhaust temp. : 180 ° C 262 ° C max Exhaust quantity: 28 t / h 47 t / h max Speed: 10.043 RPM Quick closing speed: 11,047 RPM Gearbox Generator Manufacturer LEROY SOMER KV voltage 5.25 Frequency 50 Hz Speed of 1,500 RPM maximum 1,800 RPM Power: 9,000 kVA Power factor: 0.8 Year of construction 2005 Operating hours: 16,000
Dear's Sale, T/C complate ABB TPS 57 Recon, Good condition Regards +905323642509 info@kscege ... more information
Dear's Sale, T/C complate ABB TPS 52 Recon, Good condition Regards +905323642509 info@kscege.com ... more information
51 MW - CCGT comprising 3 x 12 MW Solar Gas Turbine generator and 1 x 15 MW steam turbine generator Model : TITAN 130 Capacity : 12 MW Voltage ; 11 KV / 50 Hz Qty : 3 sets Titan 130 + 1 set STG Year : 2012 Running hr : 6000 hrs since new ... more information
2 nos. GE PG9171E 180MW / 50 Hz gas fired combine cycle gas turbine power plant, year 2004, around 31,000 hr - 34,300 hr, Steam turbine is 60MW each , and complete with heat recovery boiler. Welcome enquiry for buying only 1 or 2 gas turbine or includes engineering works. ... more information
x-travel: 310 mmy-travel: 340 mmz-travel: 170 mmControl: Heidenhain TNC 124 total power requirement: 5,5 kWweight of the machine ca.: 0,8 tdimensions of the machine ca.: mThe data for this ad was created with ModulMWS - the software solution of LogoTech oHG. ... more information