Machine name: Ball diaphragm pump used Manufacturer: Abel Type: HMD-G-50-0500 Year of Make: 2001 Degree of protection: IP 55 Speed: 1460 rpm Operating voltage: 380 V Frequency: 50 - 60 Hz Delivery pressure: 16 bar Material: Steel Drive motor: 30 kW Flow rate: 59000 L/h Dimensions: L 3,200 x W 1,500 x H 2,300 mm Empty weight: approx. 4,000 kg Tech. Documentation: Yes Condition: Used Price: On request
6 pieces Chemistry Standard Pump CNN 125-100-315 / ISO 2858-EN 22858-ISO 5199, in stainless steel 1.4408 / process design, 119 m3, FH 25 m, 15 KW, unused with documents and replacement mechanical seal ... mais informação
MasoSine®'s EcoSine pump satisfies demanding processing requirements cost-effectively, using the unique MasoSine® pumping principle. This model is a sanitary pump for pressures to 6bar (90 psi) and bi-directional operation. The sine-wave-shaped rotor creates four moving chambers which gently convey the duty fluid from the inlet port to the higher-pressure discharge port. The gate prevents any fluid passing back from the discharge side to the lower-pressure suction side of the pump. Ecosine is for sanitary duties requiring strong suction/low shear. Capacity: 125,000 liter/hour (550 US gpm) Pressures to 6 bar (90 psi) EcoSine Pump Series Features& Benefits: Exclusive sinusoidal rotor Powerful suction Large pumping chambers for fragile particulates 3A Certified Gentle, low shear product handling Safely pumps highly viscous products Very low pulsation Economical in-line main ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 MTA S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump: Cooling capacity kW 136 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70.48 Max. current (A) 119.28 Starting Current Circuit (A) 235.01 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2131 Connection Rp 3" Serial No.: 2200389888 Year of construction 2022 Condition: Optical 2, Technically ok (used ...
Plate heat exchangers GEA NT150L B-10, 1491 kg, 356 l press content, year 2009, very good condition, max. 13 bar,. ... mais informação
Process chiller / chiller air-cooled, Type: TAEevo Tech 251 P3 MTA S.p.A. TAEevo Tech 251P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. and built-in P3 Circulating pump. Cooling capacity kW 49.7 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 8.48 Available pump pressure (bar) 2.61 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 27 Max. current (A) 46 Starting Current Circuit (A) 144 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (kg) 998 Connection Rp 2 " Price: on request in Euro (plus VAT from Nettetal) – 3 months warranty Serial No.: 2200393289 Year of construction 2022 Condition: ...
Edeleanu GmbH / Shell Lube Oil Hydrotreater 1 (LHT-1) (1972/2015) Year: 1972 Make: Edeleanu GmbH / Shell Hydrotreating to produce lubricating-manufacturing oils, sulfur-free, few aromatics, light color, color stability (aging). Year of manufacture 1972 Process Design by Shell Process Engineering by Edeleanu GmbH Feed = Paraffinic or naphthenic distillates (range of Viscosity = 2 – 160 cst/40°C) Throughput max. 550 t/d (approved), 600 t/d possible (yield range 72% – 96%) Operational operating temperature = 355°C (Reactor WABT = Weighted Average Bed Temperature) Operational operating pressure = 140 bar 1987 – Capacity expansion of the C-5401 to 550 t/d (previously designed for 400 t/d) 2015 – Revamp to operate with pure Hydrogen Make-Up gas (99,99%) 2015 – New column C-5407 (separation of slops into HTFR and HTTOPP) 2021 – new furnace (F-5401) 2021 – Const ...
Sour Water Strippers (SWS-1 and SWS-2) (1981) Year: 1981 Two redundant units for removal/reduction of H2S and ammonium (NH3) from plant wastewater by using stripping steam. Year of manufacture 1981 Process Design by Shell Process Engineering by Comprimo B.V. Throughout for each SWS max. 1289 t/d (incl. 1,58 t/d NH3 and 2,82 t/d H2S) Operational operating temperature SWS-1 = 102°C, SWS-2 = 95°C Operational operating pressure SWS-1 = 0,1 bar, SWS-2 = 3,3 bar 2022 – Decommissioning
Edeleanu GmbH / Shell Fuel Gas Treater (HG Treater) (1978) Year: 1978 Make: Edeleanu GmbH / Shell Treatment of process gases (removal of H2S) by Diisopropanolamine (DIPA) washing. Year of manufacture 1978 Process Design by Shell Process Engineering by Edeleanu GmbH Throughput max. 180 t/d (DIPA-circulation max. 260 t/d) Operational operating temperature = 30 to 50°C (max. = 120°C) Operational operating pressure = 4,0 to 5,0 bar (max. = 12,5 bar) 2022 – Decommissioning
Comprimo B.V. / Shell Diisopropanolamin (DIPA) Regeneration (1983/2015) Year: 1983 Make: Comprimo B.V. / Shell Regeneration of DIPA and stripping of H2S for further processing in the Claus Units. Year of manufacture 1983 Process Design by Shell Process Engineering by Comprimo B.V. Throughput DIPA Regeneration max. 1112 t/d (DIPA with 2,79m% H2S load) Operational operating temperature = 102 to 106°C (max. 160°C) Operational operating pressure = 0,5 to 0,8 bar (max. 6,0 bar) 2015 – Complete CUI Program on main column (new coating and insulation) 2022 – Decommissioning
Comprimo B.V. / Shell 5. Shell Claus Offgas Treating (SCOT) (1983/2015) Year: 1983 Make: Comprimo B.V. / Shell Downstream minimization (H2S recovery efficiency = 94.5%) in tail gas of Claus Units 1+3. Includes operation of 2 Incinerators. Year of manufacture 1983 Process Design by Shell Process Engineering by Comprimo B.V. Throughput SCOT max. 90 t/d Offgas Throughput for each incinerator max. 11,4 t/d (2 Incinerators available) Operational operating temperature SCOT = 270 – 290°C (WABT = Weighted Average Bed Temperature) Operational operating pressure SCOT = 40 to 60 mbar Operational operating temperature Incinerators = 280 to 290°C Operational operating pressure Incinerators = 30 mbar 2015 – Replacement of complete quench tower C-3651 2022 – Decommissioning
Edeleanu GmbH / Shell 3. Sulphur Recovery (Claus-1) Year: 1956 Make: Edeleanu GmbH / Shell Conversion of the hydrogen sulfide produced in the 3 DIPA regenerators into elemental sulfur. (H2S recovery efficiency = 95.4%) Year of manufacture 1956 (1996 new furnace) Process Design by Shell, Claus Process Process Engineering by Edeleanu GmbH Operational operating throughput = 6 to 36 t/d H2S Operational operating temperature = 250 to 340°C Operational operating pressure = 0,3 bar 2022 – Decommissioning
Used stainless steel chumber filter press made by Columbit, new: 2003, after renovation, Overall dimensions: length 5000 mm, width: 1300 mm, height: 1500 mm, no technical documentation. Manual-hydraulic pressure of the plates. Press has filter plates and the frames with dimensions of 800 mm x 800 mm.
Used vibration ito Virto-Cuccolini VPB 800 1/X. Year of construction 2023. Sieve for food powders and granules. Construction: - Parts in contact with the product made of AISI 304 acid-resistant steel - Other parts made of galvanised plain steel - Cover with D200 inlet, D200 inspection and D100 vent; complete with clamping ring and silicone V-gasket - Sieve deck H=118 mm with mesh support ring, with outlet D150; Silicone gaskets - Mesh wire diameter 0.16 mm, height 2850 mm, hole 0.25 mm in AISI 304 - Mesh support ring for size 800 tensioned in AISI 304 satin finish (fin. 3). Tension rings included. - Mesh opening 0.397 MM - AISI 304 - Sieve bottom with outlet D116 - 0.73 kW, 230/400 V 50 Hz, 4-pole vibration motor - Installed on the flange spring holder and on the 3-wheel trolley made of acid-resistant steel - Control panel ON/OFF - Sieve complete with Atex components and ce ...
Used dryer Glatt WST 100/150. New 1997. Dismantled. No documentation. 2 pieces available. ... mais informação
Twin-shaft pre-press screw Type: DDA:VP-370:A270 Trough: approx. 3,000 x 660 mm, screw diameter approx. 370 mm Drive via geared motor ... mais informação
Manufacturer: PCM Type: Moineau 13L10 Nominal diameter: DN50 Flow rate: up to 13,000 l/h Operating pressure: up to 6 bar Incl. overhauled replacement pump (without motor) ... mais informação
Manufacturer: GEA Wiegand Type: 5-stage evaporator with 2-stage high concentrator Year of Make: 1979 Inlet capacity: 40,000 l/h at 6% dry matter Output (whey): ~4100 kg/h at 58% dry matter Condition: passable MORE INFORMATION AND PICTURES ON REQUEST ... mais informação
Content: 1.000 Ltr. Working pressure: Max. steam pressure 1.1 bar at 50°C, 1.3 bar at 55°C Material: Stainless steel, 1.4404 inner tank, 1.4301 frame and outer jacket Design: cubic, upright, on 4 feet, with welded construction for access by forklift or pallet truck, Insulating jacket with perlite insulation, electrically heated up to 120 °C, 2,000 W, 230 V, Inner tank lined with ETFE coating Spout with disc valve DN 80 reduced to DN 50, cover DN 400, 1 x Safety Valve, 1 x Camlock Coupling 1", Total weight 381 kg Last Purpose: Food Height: approx. 1,670 mm Width/Length: approx. 1,200 mm/1,100 mm