Description: |
Multivalent steam boiler system 2 x 10 MW GETEC pulverulent fuels, natural gas
used machine
Multivalent steam boiler system 2 x 10 MW, AS NEW
For dusty fuels or natural gas H.
2 identical lines:
Single-flame tube boiler with economiser
Fuel so far: lignite dust
Calorific value Hu: 22,190 kJ/kg
Ash content: 3.0 % – 3.5 %
Rated thermal input: 19.5 MW FWL (2 x 9.75 MW FWL)
Steam output: approx. 24 t saturated steam, 20 bar ü
depending on the extent of condensate recirculation
Preset also for natural gas operation H
Calorific value HS: 11.4 kJ/Nm³ (calorific value Hi 10.4 kJ/Nm³)
Rated thermal input: 19.5 MW (2 x 9.75 MW FWL)
Steam output: approx. 24 t saturated steam, 20 bar ü
depending on the extent of condensate recirculation
The change of the burner operation is carried out by changing a
fitting piece on the burner.
Boiler 1 and boiler 2 can be fired at the same time with different
fuels.
If desired, the contents of both fuel silos can also be burned via
just one boiler.
In principle, all organic, dusty substances are suitable for the
burner technology used.
Among other things, the like can be used:
+ Residues from the production of sugar products ("white powder")
+ Treated municipal sewage sludge (after drying and grinding)
+ Sawdust
+ ...
The manufacturer can offer solutions for the fuel changeover at any
time.
We establish contact.
The steam boiler system generates saturated steam at 20 bar ü
(pressure PS: 25 bar); for the possible addition of a wet steam
turbine, a reserve area was provided in the boiler house.
Such a turbine can be added at any time.
MAIN COMPONENTS INCLUDE:
2 x Single-flame tube boilers
Year of construction 2015
Manufacturer: Standardkessel Köthen GmbH
Type: Large water boiler with a flame tube (two-speed) and downstream
economizer
Permissible operating pressure (PS): 25 bar
Permissible operating temperature: 226 °C
Permissible steam output per boiler: 13.5 t/h saturated steam
2 x Burner
Year of construction 2015
Manufacturer: Carbotechnik Energiesysteme GmbH
Fuel: lignite dust or natural gas
1 x Fireplace
Height above ground: 49 m
Outlet area: 0.785 m² (Ø = 1,000 m)
Construction: Stainless steel double fireplace
1 x Water treatment plant
Year of construction 2009
Manufacturer: BKG Wassertechnik GmbH
consisting of 2 x reverse osmosis system and downstream softening
system
1 x Steel hall and stages incl. Ì
2 x BKS silo each 300 m³, pressure shock resistant
2 x natural gas / BKS fired steam boilers, saturated steam, pressure
PS 25 bar
2 x Economizer
1 x Flue gas dust collector with aschesilo and filling
1 x Steel fireplace height 49m
1 x Feed water tank 30 m³ with thermal deaeration
2 x Feed water pumps
1 x Compressed air supply system (with 2 compressors)
2 x Combustion air blower
2 x Recirculation blower (for natural gas operation)
2 x positive displacement blowers (conveying air)
1 x Water treatment plant consisting of reverse osmosis with
downstream softening
1 x Control room equipment
1 x Process control system
1 x Emission monitoring system (continuous measurement of CO and
dust)
Multivalent steam boiler system 2 x 10 MW, AS NEW
For pulverulent fuels or natural gas H.
2 identical lines:
Single-flame tube boiler with economiser
fuel so far: Brown coal dust
calorific value Hu: 22,190 kJ / kg Ash
content: 3.0% - 3.5%
Combustion heat
output: 19.5 MW FWL (2 x 9.75 MW FWL) Steam output: approx. 24 t
saturated steam, 20 bar g
depending on the extent of the condensate return
Preset also for natural gas operation H
Calorific value HS: 11.4 kJ / Nm³ (calorific value Hi 10.4 kJ /
Nm³)
Combustion heat
output: 19.5 MW (2 x 9.75 MW FWL) Steam output: approx. 24 t saturated
steam, 20 bar above sea level
depending on the extent of the condensate return
The burner operation is converted by changing a fitting piece on the
burner.
Boiler 1 and boiler 2 can be fired with different fuels at the same
time.
The contents of both fuel silos can also be burned using just one
boiler, if desired.
In principle, all organic, dusty substances are suitable for the
burner technology used. Among other things, the following
can be used:
+ residues from sugar powder production ("white powder")
+ processed municipal sewage sludge (after drying and grinding)
+ sawdust
+ ...
The E553254 manufacturer can offer solutions for changing fuel at any
time.
We make contact.
The steam boiler system generates saturated steam at 20 bar g
(pressure PS: 25 bar); A reserve area was provided in the boiler house
for the possible addition of a wet steam turbine.
Such a turbine can be added at any time.
MAIN COMPONENTS ARE AO:
2 x single-flame tube boilers,
each built in 2015
? Manufacturer: Standardkessel Köthen GmbH
Type: Shell boiler with a flame tube (two-chamber) and downstream
economizer
Permissible operating pressure (PS): 25 bar
Permissible operating temperature: 226°C
Permissible steam output per boiler: 13.5 t/h saturated steam
2 x burners
Each year of construction 2015
Manufacturer: Carbotechnik Energiesysteme GmbH
Fuel: Lignite dust or natural gas
1 x chimney
Height above ground: 49 m
Exit area: 0.785 m² (Ø = 1,000 m)
Construction: Stainless steel double chimney
1 x water treatment system
built in 2009
Manufacturer: BKG Wassertechnik GmbH
consisting of 2 x reverse osmosis systems and a downstream softening
system
1 x steel hall and stages incl. Ì
2 x BKS silo each 300 m³, pressure shock resistant
2 x natural gas / BKS-fired steam boiler, saturated steam, pressure PS
25 bar
2 x economizer
1 x flue gas dedusting system with ash silo and filling
1 x steel chimney height 49m
1 x feed water tank 30 m³ with thermal degasser
2 x feed water pumps
1 x compressed air supply system (with 2 compressors)
2 x combustion air blowers
2 x recirculation
blowers (for natural gas operation) 2 x rotary piston blowers
(conveying air)
1 x water treatment system, consisting of reverse osmosis with
downstream softening
1 x control room equipment
1 x process control system
1 x emission monitoring system (continuous measurement of CO and Dust)
seller offer No. resale 157160053
|