Sodiet SM35 Steam boiler Serial: 5741 2005, volume 566L, 19.6Bar, max 188'C, 1230Kgs, with Weishaupt burner
Babcock Wanson 43 Steam boiler Serial: 16285 - PF118144 2013, max fluid temp 192'C, runs on natural gas, useful power 300Kw, steam boiler, TYPE NBWB, with RS44 burner and Grundfoss pump, also comes with Babcock Wanson 100l tank,
Compact steam generator system (installed in a container (L270 x W240 x H280) Achievement Capacity: 300 kg/h Water capacity: approx. 32.3 l Operating overpressure: 10 bar Feed water module with control cabinet and stainless steel feed water tank BWT softening system Stainless steel fireplace insulated, approx. 8 m
SUMAB is currently offering a horizontal steam generator. Technical details: Capacity 1500 kg/h, allows you to produce steam in a short period of time. Pre-installed accessories are ready to run. A two part platform for easy assembly on site. Includes: water softening device, condensate tank, cavitation preventing pump, by-pass group with float trap, all fittings and piping connections.
Available two units of this SIAT RECOPACK recovery boiler. This boiler recovers the heat from the exhaust gases of turbines or engines, but it doesn't have burner to produce his own heat. They are disassembled and ready to be load. Power 493kW pressure 12 bar Capacity 5065 l YOM 2009 Model Recopack
Type: Year of Make: 1992 Fabr. Item no.: 54386Power: 1.340 kW Ab. Temp.: 120°C Ab. Pressure:m 8 bar Fully functional. WEISHAUPT Gas Burners
Kettle: Manufacturer: LOOS Type: UT-L 14 Manufacturer Part Number: 99092 Year of Make: 2005 Power: 1500 kW Ab. Max. pressure: 6 bar Test pressure: 9.6 bar Max. permissible Temperature: 110 °C Volume: 1,700 l Burner: Manufacturer: Max Weishaupt GmbH Type: GL8/1-D Manufacturer Part Number: 5462558 Year of Make: 2005 Power: min. 400 kW, max. 2275 kW Gas Type: N
Kettle: Manufacturer: LOOS Type: UL-S 2000 Manufacturer Part Number: 99095 Year of Make: 2005 Capacity: 1,600 kg of steam Ab. Max. pressure: 10 bar Test pressure: 19 bar Max. permissible Temperature: 184 °C Volume: 3,315 l Burner: Manufacturer: Max Weishaupt GmbH Type: GL8/1-D Manufacturer Part Number: 5462558 Year of Make: 2005 Power: min. 400 kW, max. 2275 kW Gas Type: N
A steam boiler of the brand Sillert + Jamert is sold. The steam boiler works without any problems. Specifications: - Year: 1973 - Power: 8 tons of wet steam - Pressure: 10 bar - Switched to gas in 2017
Type: K 8 – 1500 Fabr,-Nr.: 0899377 Year of construction: 1999 Power: 1,500 kW Heating area: 91.5 m² Fuel: Wood, Bark Ab. Overpressure: 3 bar Permissible, VL-Temp.: 110 °C If required, electrostatic precipitators and stainless steel chimneys can be supplied for an additional charge of €30,000.
Rapid steam generators Certuss / Universal 1800 TC EG NG/ 2 to/h 25 bar / 2017 used, sale in current condition, price ex location
1 STERLING STERLCO used diathermic oil boiler with electric heating type S-9026-J0 serial nr. 95E5517 Dual zone Heating Capacity Zone 1: 18 KW Heating Capacity Zone 2: 36 KW Total Heating Capacity: 54 KW Pump Motor (Zone 1): 1.5 KW / 2 HP Pump Motor (Zone 2): 1.5 KW / 2 HP complete with circulation pumps and high accurency temperature controlers 1" oil circulation pipes (up to 110 L/min) 1" vent pipes (up to 110 L/min)
V195 1 electric steamboiler Loos/Germany EUR 1.500,- loaded year 1990, 6 bar, 164°C, capacity 115 kg/h, 81 kW, 380V/50 Hz, volume 85 ltr. EUR 1.500,- loaded ex works V196 1 electric steamboiler Roucka-Slatina/Czech. EUR 1.500,- loaded year 1993, 9,5 bar, 177°C, capacity 120 kg/h, 90 kW, 380V/50 Hz EUR 1.500,- loaded ex works
see performance data on photo with data
Allison Detroit Diesel Turbine Allison Type 501 KB Year of manufacture 1980 alternator RATED 3860KW alternator DUTY 3355KW Alison turbine = 4380 HP --> heating oil INPUT RPM 14210 OUTPUT RPM 1500 Number of hours 600H of operation 10 KV cell (alternator output) Deutz diesel 160 HP (turbine launcher) 10 kW generator set – Deutz engine (auxiliary power)
Steam capacity: 1500 kg/h Max Zul. Pressure: 13 bar with Weishaupt oil burner Type: L7Z and Speck/Feedwater Pump Year of Make: 2003 Boiler was operated in a boiler keeper / training facility! Less than 200 operating hours Price: VHB
Multivalent steam boiler plant 2 x 10 MW, AS GOOD AS NEW, 2015, Dusty fuels, Natural gas, Raw material storage, Burner, Standard boiler, Economiser, Osmosis system, Steel hall Description Multivalent steam boiler system 2 x 10 MW, AS GOOD AS NEW For dusty fuels or natural gas H. 2 identical lines: Single-flame tube boiler with economiser Fuel so far: lignite dust Calorific value Hu: 22,190 kJ/kg Ash content: 3.0 % – 3.5 % Rated thermal output: 19.5 MW FWL (2 x 9.75 MW FWL) Steam output: approx. 24 t saturated steam, 20 bar g depending on the extent of condensate recirculation Preset also for natural gas operation H Calorific value HS: 11.4 kJ/Nm³ (calorific value Hi 10.4 kJ/Nm³) Rated heat output: 19.5 MW (2 x 9.75 MW FWL) Steam output: approx. 24 t saturated steam, 20 bar g depending on the extent of condensate recirculation The conversion of the burne ...
Permissible operating overpressure: 6.0 bar Permissible flow temperature: 120 C Permissible boiler power: 400 kW Heating output: 444 kW Content: 380 liter Burner: Weishaupt RGL 3/1 - E Year: 1994 Fuel: Heating oil EL and natural gas Subject to prior sale - errors possible Internal Reference Number: D-1176
Steam generator, steam boiler, boiler stove used Manufacturer Gebr. Weißbach GmbH Year of construction 1993 Ab. Steam generation 1700 kg / h Ab. Pressure 6 bar Water capacity 3795 l zul Vorlauftemp. 165°C zul heat output 1.1 MW Dimensions: 4000 x 1900 x 2400 mm Changes and errors in the technical data, information and prices as well as prior sale reserved.
Qty. 1 Second-hand power plant including boiler (BFB – boiler: bubbling fluidized bed) Mfc.: Foster Wheeler, Siemens, Raumaster, YIT Corporation, Honeywell, Built: 2001, 2002, 2006, 2009 Revision: 2009 Insulation removed in 2018 BFB Boiler – 88 MW Steam turbine – 22.5 MW Main Steam Cycle BFB boiler K7 – Some parts removed and storaged indoor at the paper mill area – Boiler is made electrically safe (cables cut) – Dry conservation ongoing since 2014 (tubes filled with nitrogen, dry air circulation) – Steam Turbine VP4 (in storage) Generator (in storage) Power Plant – Function Primary function is to produce steam for the Paper Mill reliable and economically Secondary functions: Burning of the Paper Mills (PM) waste wood Incineration of sludge from the PM: WWTP Production of flue gas to the PCC (precipitated calcium carbonate) plant Electricity product ...