Manufacturer : BEARWARD Model : VTA 28 G5 Power : 500 KW/625KVA Engine: Cummins 12Cylinder Turbo Diesel Year built in :1993 Operating hours:61h RPM : 1500 U/Min. Frequency : 50 Hz Voltage : 230/400 volts Complete with controls Incl. diesel tank in the base frame
Cooling: Water Speed: 1500 1/min Battery voltage: 24V Tank: approx. 800 litres Generator: Leroy Somer TAL-A44J Voltage: 400/231 V, 50 Hz Manual/automatic control with DEEP SEA DSE7320 and generator circuit breaker, socket distribution. The generator is equipped with sockets, the total power is removable via a terminal strip. Device is primarily intended for export. New device, unused Warranty: 1 year or 1000 hours of operation, whichever comes first. Immediately available! Subject to prior sale - errors possible! Ref. No.: E-1004-62
Power: 1400 kVA at 60 Hz, 1200 at 50 Hz - Currently set to 50 Hz! Hours: 778 Cooling: Water Speed: 1500 1/min Tank: 2000 liters Generator: Leroy Somer LSA 50 VL 10 Voltage: 400/231 V, 50 Hz Control Panel: LS 2000 A Generator, DSE 8610 MKII Deep Sea Control Was used as an emergency power system, therefore few operating hours Control and circuit breaker new! Subject to prior sale - errors possible! Internal Reference Number: E-1004-69
BHKW in container with Cummins diesel engine Lorey Somer generator 250KVA 1500U / min 50 hertz Storm Steuerung, arrangement is equipped with emergency cooler zusaetzl. regularly waited to zeit 21000 company hours. arrangement is operational and available immediately. for other questions I stand to them to verfuegung under 01727265324
NEW injection pump 0402066725(= PES6P110A120RS3336-1) Contact= MIW GmbH Motoren-Instandsetzungs-Werk Nord-West-Ring 8 D-27404 Zeven/Germany phone: 0049(0)4281-950583 fax : 0049(0)4281-950585 info@miw-zeven.de abc.miw-zeven
New injection pump 0402 066 725(=PES6P110A120RS3336-1) NET 2.950,-EURO 6 x new injectors 0432 191 342 (Cummins # 408931500) net / piece 215,-EURO Mail: info@miw-zeven
C110 D5 Enclosed A040P845 Genset Model C110 D5, 110kVA Standby, 100kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTA5.9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274C, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mo ...
C150 D5 Enclosed A047W023 Genset Model C150 D5, 150kVA Standby, 136kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G6 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274E, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
C170 D5 Enclosed A047W024 Genset Model C170 D5, 170kVA Standby, 155kVA Prime, Enclosed Emergency Standby Power (ESP) Emissions Level : No Certification Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine 6BTAA5.9G7 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Co ...
C175 D5e Enclosed A049J778 Genset Model C175 D5e, 175kVA Standby, 160kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274F, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Wat ...
C200 D5e Enclosed A049J779 Genset Model C200 D5e, 200kVA Standby, 182kVA Prime, QSB7G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SIIIA Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSB7G5 Engine Air Cleaner - Duty Rating : Heavy Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UC274H, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% W ...
C275 D5 Enclosed A049K225 Genset Model C275 D5, 275kVA Standby, 250kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator UCD274K, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
C330 D5 enclosed A048T878 Genset Model C330 D5, 330kVA Standby, 300kVA Prime, QSL9G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : TAL 4g Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSL9G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC4D, 12 Leads, 50 Hertz (Hz), 190 - 208V and 380 - 416V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclosure Critical Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture : 50% Antifreeze, 50% Water ...
C350 D5 Open A019J715 Genset Model C350 D5, 350kVA Standby, 320kVA Prime, NT855G6, Diesel, Open Emergency Standby Power (ESP) Emission Level; No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NT855G6 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4E, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole, End ...
C400 D5 Open A019J729 Genset Model C400 D5, 400kVA Standby, 360kVA Prime, NTA855G4, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G4 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HCI4F, 50Hz, 12 Leads, 380-415V, 163C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 630A, 690V IEC, 600V UL, 4Pole ...
C400 D5e Enclosed A029Z631 Genset Model C400 D5e, 400kVA Standby, 364kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC4F,50Hz,12 Leads,190 - 220V & 380 - 440V125C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 630A,690V IEC, 600V UL,4 P ...
C440 D5 Open A019J736 Genset Model C440 D5, 440kVA Standby, 400kVA Prime, NTA855G7, Diesel, Open Emergency Standby Power (ESP) Emission Level, No Certification Local Code and/or Regulation, CE Output Voltage, 400/230, 3Phase, Wye, 4Wire Engine NTA855G7 Engine Air Cleaner-Duty Rating, Normal Duty Engine Coolant Heater, 240V Main Generator HC5C, 50Hz, 12 Leads, 380-415V, 150C, Emergency Standby Power (ESP) Exciter/Voltage Regulator-Torque Match Exhaust System Silencer Grade, Industrial, Flange BS10, Inlet 6 Inch, Outlet 6 Inch, in-Line Entry Exhaust System Accessories, Bellows Cooling System Genset Mounted Radiator, 50C / 122F, Genset Mounted Engine Coolant Mixture, 50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device 800A, 690V IEC, 600V UL, 4P ...
C500 D5 Enclosed Genset Model Item C500 D5, 500kVA Standby, 455kVA Prime, 0, 0, QSZ13G5, Diesel, Enclosed Emergency Standby Power (ESP) Emissions Level : EU SII Local Codes and/or Regulation : CE Output Voltage : 400/230, 3 Phase, Wye, 4 Wire Engine QSZ13G5 Engine Air Cleaner - Duty Rating : Normal Duty Engine Speed Governing : Isochronous Electronic Governor Engine Coolant Heater : 240V Sub-Base Anti-Vibration Mounts None Supplied Main Generator HC5C, 12 Leads, 50 Hertz (Hz), 190 - 220V and 380 - 440V, 163C, Emergency Standby Power (ESP) Generator Accessories Voltage Regulator - Torque Match Main Generator Heater : None Supplied Genset Housing Sound Attenuated, Steel, Munsell Green Exhaust System Silencer Grade : Enclo ...
C550 D5e Enclosed A029Z751 Genset Model C550 D5e, 550kVA Standby, 500kVA Prime,QSX15G8,Diesel,Enclosed Emergency Standby Power (ESP) Emission Level,No Certification Local Code and/or Regulation,CE Output Voltage,400/230, 3 Phase, Wye, 4 Wire Engine QSX15G8 Engine Air Cleaner-Duty Rating,Normal Duty Engine Speed Governing,Isochronous Electronic Engine Coolant Heater,240V Main Generator HC5D,50Hz,12 Leads,200V & 400V150C,Emergency Standby Power (ESP) Voltage Regulator,Torque Match Main Generator Heater,None Supplied Genset Housing Sound Attenuated,Steel,Munsell Green Cooling System Genset Mounted Radiator,50C / 122F,Genset Mounted Engine Coolant Mixture,50% Antifreeze, 50% Water Primary Electrical Isolation Device One Circuit Breaker Primary Electrical Isolation Device-1 800A,690V IEC, 600V UL,4 Pole,100%,Left C ...
Cummins KTA38 M2 Building year 2007 with only 35000 hours STD crankshaft power is 1300 HP @1800 rpm
Many thanks for your interest in our machinery, please find below our offer: Combined heat and power plant (CHPU)with up to 500KW A total of 3 independent cogenerators with combined heat and power; Electricity & hot water With only max 13280 operation hours!!! Operation is done with heating oil !!! Permission available Total power approx. 500kw, cascade connection, in depending on power requirements, the various energy producers gradually switch on and regulate themselves on the performance. At peak load, all 3 systems work in parallel with full output Ideal for power supply in remote areas without public supply or as emergency power supply with simultaneous heat recovery if desired. Each engine has a heat exchanger. If heat is not needed, it can also be removed. The plant is constructed and ready, accordingly control etc. Top maintained. Spare parts for maintenance etc ...