Agilent - AriaDx Real Time PCR K8930AA - Thermal Cycler

medical equipment / medical equipment

Agilent AriaDx Real Time PCR K8930AA Thermal Cycler; ; Year of manufacture: 2021; Model: K8930AA; With computer (ARIADX software installed); No cables; ; Excitation source: 8 dye-specific LEDs per optical module; Detectors: 8 photodiodes; Reaction volume: 10 to 30 μl; Compatible chemistries: SYBR ...

TOP
Seller

Manufacturer:

Model:

Type of machine: Agilent - AriaDx Real Time PCR K8930AA - Thermal Cycler

item-No.: 170320879

Quantity: 1

Date: 14.10.2026

Location: 59710 AVELIN

Auction start price: 800 EUR

Auction Price: 800 EUR

Seller-item-No.:4a502bc3-699e-4758-b13e-351f169e0a68

Go to auction:

End of auction: 05.11.2026 - 17:05

Agilent AriaDx Real Time PCR K8930AA Thermal Cycler;
;
Year of manufacture: 2021;
Model: K8930AA;
With computer (ARIADX software installed);
No cables;
;
Excitation source: 8 dye-specific LEDs per optical module;
Detectors: 8 photodiodes;
Reaction volume: 10 to 30 μl;
Compatible chemistries: SYBR and TaqMan;
Thermal system: 6 Peltier modules (25.0 to 99.9 °C);
Heating speed: 6.0 °C/s;
Cooling rate: 2.5 to 3.0 °C/s;
Thermal uniformity: ± 0.4°C;
Data acquisition time: < 3 seconds for all channels;
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz;
Dimensions: 50 cm (W) x 46 cm (D) x 42 cm (H);
Weight: 23 kg;
Sample containers: 96-well plates, strip tubes, 0.2 mL tubes;
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing);
;
The device is fully functional, but the intervention of an AGILENT technician is necessary for its return to service.
An internal test has been carried out; everything is compliant, except for the following error message: \"Block contamination error\";
;
Internal reference: FA-2481;
Auction-ID: A1-50994-1004
Share this machine on Facebook:
Agilent AriaDx Real Time PCR K8930AA Thermal Cycler;
;
Year of manufacture: 2021;
Model: K8930AA;
With computer (ARIADX software installed);
No cables;
;
Excitation source: 8 dye-specific LEDs per optical module;
Detectors: 8 photodiodes;
Reaction volume: 10 to 30 μl;
Compatible chemistries: SYBR and TaqMan;
Thermal system: 6 Peltier modules (25.0 to 99.9 °C);
Heating speed: 6.0 °C/s;
Cooling rate: 2.5 to 3.0 °C/s;
Thermal uniformity: ± 0.4°C;
Data acquisition time: < 3 seconds for all channels;
Power supply: 100-240 V AC, 50/60 Hz Frequency: 1100 Hz;
Dimensions: 50 cm (W) x 46 cm (D) x 42 cm (H);
Weight: 23 kg;
Sample containers: 96-well plates, strip tubes, 0.2 mL tubes;
Operating conditions: 20 – 30 °C, relative humidity: 20 – 80 % (non-condensing);
;
The device is fully functional, but the intervention of an AGILENT technician is necessary for its return to service.
An internal test has been carried out; everything is compliant, except for the following error message: \"Block contamination error\";
;
Internal reference: FA-2481;
Auction-ID: A1-50994-1004
seller offer No. resale 4a502bc3-699e-4758-b13e-351f169e0a68
Share this machine on Facebook:
approved
dealer

Seller

logo dealer

Surplex GmbH


40472 Düsseldorf
Germany

RESALE member since 2006

  • machine list (20068)