We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Manufacturer:
(Category: 1800)
used
KNF N735.3 AT.18 diaphragm vacuum pump; ; Flow rate (max.): 50 l/min; Vacuum limit (max.): 67 mbar (abs.); found following our test of good functioning (see photo); ; Clean operation; Signs of wear related to the age of the equipment; ; Internal reference: FA-1054; Auction-ID: A1-50994-1121
used
Perkin Elmer Lambda 35 UV/VIS Spectrometer; ; Untested equipment in good aesthetic condition.; Without a computer; ; Internal reference: FA-2509; Auction-ID: A1-50994-1018
used
HANNA phosphate photometer HI97713, up to 2.50 mg/L; ; New equipment in its original packaging; ; HI97713 comes with 2 measuring cups, plastic caps and caps and batteries.; ; Range: 0.08 to 2.50 mg/L; Resolution: 0.01 mg/L; Accuracy at 25°C: ±0.04 mg/L ± 4% of reading; Method: Ascorbic acid; Light Source: LED with 610 nm Narrow Bandwidth Filter; Light Detector: Silicon Photocell; Batteries/Life: 3 x 1.5 V AA / >800 measurements without backlight; On-demand memory: Up to 50 bars for on-screen recall; Self-extinguishing: After 15 minutes of non-use / After 30 minutes of non-use before a measurement; Dimensions /Weight: 142.5 x 102.5 x 50.5 mm / 380 g; ; Internal reference: FA-1663; Auction-ID: A1-50994-1177
used
Hydrogen generator H2 40H Parker Hannifin domnick hunter; ; Year of manufacture: 2018; ; Type: Hydrogen Fuel Gas Generator; Model: 40H; Max Flow Rate: 250ml/min; Pressure: 0 to 100 psi; Power: 185 W; Max. operating ambient temperature 5° to 40°C; Output Port 0.125\" compression fitting; Dimensions: 34.2 x 45.6 x 35cm; Weight: 23kg; ; Equipment not tested.; Plan for a technician to return to service; ; Internal reference: FA-2495; Auction-ID: A1-50994-1104
used
BERTHOLD TECHNOLOGIES MITHRAS LB 940 Multimode Microplate Reader; ; Plate reader for luminescence and fluorescence; Number: 38099-33; ; Untested equipment; Without a computer; Without software; ; Internal reference: FA-1494; Auction-ID: A1-50994-1023
used
CSL-GDVH CLEAVER SCIENTIFIC Gel Dryer (drying surface 21 x 31 cm); ; New equipment in its original packaging; ; Model: CSL-GDVH for electrophoresis system; Product code: 241; Temperature increment: 0.1°C; Temperature Calibration: Yes; Temperature uniformity: ± 0.2°C; Timer: 1 to 999 min; Drying surface (Midi format): 21 x 31 cm; Operating Temperature Range: Ambient to 90°C; Dimensions (W x H x D): 30 x 36 x 8 cm; ; Internal reference: FA-2608; Auction-ID: A1-50994-1087
used
Set of 5 stainless steel clamps for stirring platform - 100 ml bottle; ; For orbital lab shaker/back and forth; New equipment in its original packaging; ; Internal reference: FA-1691; Auction-ID: A1-50994-1111
used
Microplate washer Microplate washer Manufacturer: Agilent Model: BioTek 50TS16 Year: 2023 Syringe Pump Touch screen control Number of reagents: 1 to 3 24 to 384 well plates Process: • Optimized cellular lavage • Pad change 3 times • Stirring and soaking • Strip wash Overall dimensions (W x D x H): 356 x 406 x 165 mm Weight: 20 kg Incoterm: FCA Auction-ID: A1-51057-16
used
OLYMPUS IMT-2 Inverted Microscope for Parts; ; Model IMT2; Non-functional - for parts; ULWCD phase contrast 0.30; ; Binocular head; ; 4 lenses - average condition:; NIKON 4X; NIKON 10X; NIKON 20X; NIKON 40X; ; 100w BH2-RFL-T2 High Pressure Mercury Burner; ; Internal reference: FA-2500; Auction-ID: A1-50994-1151
used
Heidolph Polymax 2040 Stirrer; ; Movement: wave; Rotational speed: 2.5 – 50 rpm (digital setting); Operating Mode: Timer or Continuous; Angle: 5/10º; Non-slip rubber mat included; Load capacity: max. 10kg; ; Platform dimensions (W) x D: 39 x 34cm; Dimensions (W) x D x H: 42.6 x 43.5 x 20.8cm; ; Internal reference: FA-668; Auction-ID: A1-50994-1031
used
Power Supply Minis 150VS Major Science; New equipment in its original packaging; Smart Minis 150V power supply for electrophoresis; Internal reference: FA-1670 Auction-ID: A1-50994-1084
used
Gilson Microman E M100E Pipette 10-100 μl; ; Variable volume pipette 10-100 μl; Uncalibrated; In its original box; ; Internal reference: FA-1503; Auction-ID: A1-50994-1130
used
BETTER CD-310 Portable Pen Type Digital Conductivity Meter; ; New equipment in its original packaging; ; Model Number: CD-310; Measuring range 0~999 μs/cm; Resolution: 1 μs/cm; Accuracy: ± 2% F.S; ATC: 0~50°C; Working temperature: 0 to 50°C, RH<95%; Power: 4X1.5V (AG-13 type coin cell battery); Calibration: 1 point; Dimension: 1806533mm; Weight: 117g; ; Internal reference: FA-2440 Auction-ID: A1-50994-1056
used
EPS 600 Electrophoresis Power Supply Pharmacia Biotech; ; Regulates maximum voltage, current, and power with automatic crossover to preset limits; Output ranges: voltage - 0-600 V DC; current 0-400mA; power 0-100W; Programming ranges: voltage - 6-600 V DC; current 1-400 mA; power 1-100W; hour 00:01-500h; ; Internal reference: FA-875; Auction-ID: A1-50994-1085
used
Metrohm 730 Sample Changer Titration + SC Controller; ; Metrohm 730 Autosampler; SC Controller; ; Without a catheter; Without software; ; Internal reference: FA-557; Auction-ID: A1-50994-1162
used
Disintegration tester for tablets with timer Manufacturer: Kraemer Type: DES-1 Year: 1999 Elec: 230V / 50 Hz Power on, timer OK Does not heat up Auction-ID: A1-50994-60
used
Edwards E2M1.5 Vacuum Pump; ; Model E2M1.5; Manufacturer Code: A37122919; Final pressure manufacturer: 1 × 10-3 mbar; Ballast gas I: 8 × 10-3 mbar; Oil Capacity Range: 2,000 × 10⁻4 m³ to: 2,800 × 10⁻4 m³; Maximum continuous outlet pressure: 1,500 × 10⁵ Pa; Weight: 14 kg; Sound Level: 55 dBA, 50 Hz; External dimensions (W) x D x H: 35 x 20 x 25 cm; Raised void: 480.0 x 10-3 mbar. (0.48 mbar); ; With new oil changed on 11-09-25; with filter; ; Internal reference: FA-2326; Auction-ID: A1-50994-1119
used
CT 110 KIMO Tachometer; ; Optical measuring range - 60 to 60,000 rpm and contact - 30 to 3,000 rpm; 5-key keyboard; Power supply: 4 x AAA, LR03, 1.5V batteries; Operating temperature: 0 to +50°C; Storage temperature: -20 to +80°C; Weight 190g; ; Internal reference: FA-1225; Auction-ID: A1-50994-1167
used
Power Supply Minis 150VS Major Science; New equipment in its original packaging; Smart Minis 150V power supply for electrophoresis; Internal reference: FA-1669 Auction-ID: A1-50994-1086
used
RETSCH stainless steel test sieve 100x40mm - 224 μm; ; New equipment in its original packaging; ; Reference: 60.106.000224; Frame Material: Stainless Steel; Quantity: 1/box; For use with (Equipment): AS 200 Vibration Agitator; Height (metric): 40mm; External (metric) diameter: 100mm; Porosity: 224 μm; ; Internal reference: FA-1712; Auction-ID: A1-50994-1170
used
BOD OxiTop 12 WTW Meter Measurement; ; Scale: 0 to 4000 mg/l; 5-day data collector; Automatic start as soon as the temperature reaches 20°C; Operating temperature (metric): 5°C to 50°C; ; Included:; 12 OxiTop measurement units; universal power supply; 10 sample vials; 10 rubber sleeves; 10 stirring bars; ; Without agitator; ; Internal reference: FA-2191 Auction-ID: A1-50994-1024
used
WTW OXI 3205 Portable Oximeter + Cellox 325 Probe; ; With Cellox 325 probe; Waterproof dissolved oxygen measuring instrument; ; Battery Type: 4 x 1.5V AA Rechargeable Batteries or 4 x 1.2V NiMH Rechargeable Batteries; Atmospheric pressure compensation and correction: Automatic from 500 to 1100 mbar; Protection class: IP 67; Display Screen: Backlit Graphic LCD; Dissolved O2 measurement range: 0.00 to 90 mg/L; Dissolved O2 accuracy: ±0.5%; Dissolved O2 resolution: 0.01, 0.1mg/L; Temperature Accuracy/Accuracy: ±0.1°C; Operating/operating/operating temperature: -5 to 50°C; Net weight: 2 KG; ; Internal reference: FA-1607; Auction-ID: A1-50994-1178
used
AQUADEM EFP205L filter panel with cartridges; ; With resistivity meter . 2LD; With 2 pressure gauges upstream and downstream; dimensions: 663 x 173 x 310; With 2 AQUADEM E100 regenerative demineralizers - resin volume: 8 liters; ; Resin to regenerate; ; Internal reference: FA-2619; Auction-ID: A1-50994-1095
used
Filter holder and cartridge filters in 316L stainless steel Manufacturer: unknown Inner Diameter (mm): 99 Air outlet diameter (mm): 25 Outer Diameter (mm): 165 Height (mm): 620 Interior Height (mm): 390 Sold with 4 cartridges ( 0.1 mm / 0.5 mm / 1 mm / 2 mm ) Auction-ID: A1-50994-71
used
Turbidity meter HACH LANGE 2100AN IS; ; Range: 0 - 10000 NTU; Repeatability: ± 1% of the reading or ± 0.01 NTU, whichever is greater; Printer: Integrated (thermal, 58 mm, up to 28 columns); ; Without calibration set; No paper in the printer; ; Internal reference: FA-2134 Auction-ID: A1-50994-1160
used
Stainless steel filter Manufacturer: unknown Height (mm): 140 Inner Diameter (mm): 70 Air inlet diameter (mm): 11 Air outlet diameter (mm): 8 Auction-ID: A1-50994-78
used
Barcode Reader Manufacturer: Thermoscientific Model: VisionMate HSX Year: 2023 Overall dimensions (W x D x H): 185 x 225 x 205 mm Equipment weight: 2 kg Incoterm: FCA Auction-ID: A1-51057-19
used
Metrohm 809 Titrando Dual Port Titrator; ; Untested equipment; ; Internal reference: FA-2517; Auction-ID: A1-50994-1161
used
Bunsen AES securos mouthpiece + pedal; ; Grade: SCU 6001000; Rated Heat Load: 1300W; Gas consumption: 102g/h; ; Internal reference: FA-1561; Auction-ID: A1-50994-1065
used
Gene Quant pro RNA/DNA BIOCHROM calculator; ; Pharmacia Gene Quant pro RNA/DNA calculator.; Technical characteristics: ; 100-240 V; 50/60 Hz; 80 VA.; External dimensions (D)x(H)x(W): 34 x 16.5 x 26.5 cm.; ; Equipment not tested, not calibrated; ; Internal reference: FA-1761; Auction-ID: A1-50994-1110