Bonfiglioli PK-V 0524 – VIS 06030 inspection and leak testing
(vaccum/pressure) machine for vials, etc. The machine checks for the
presence of micro-leaks, i.e., microscopic holes or cracks in the
structure of the pack that could allow either the product to leak out
or the ingress of substances from the external environment. The
microfractures in packs are generally of irregular shape, and
therefore cannot be easily classified accordingly to their physical
dimensions; for this reason they are defined by the quantity of fluid
which can leak in or out within a given unit of time. The machine
performs also visual inspection to detect defects in the cap, cosmetic
defects on the container surface, verify the fill level, and inspect
the contents for particles presence and product color. Includes infeed
& outfeed rotary table, required air pressure 6 bar, electrics
400V/50Hz/3Ph, installed power 15 kW, required floor space approx.
7063 x 3096 mm (LxW), machine height approx. 2802 mm, capacity up to
100 vials per minute, includes format parts for vials Ø16 mm x H38 mm
(2R), Ø22 mm x H57 mm & Ø42.4 mm x H78 mm.